A rustic house with a red tiled roof and two chimneys in warm sunset light.

Gas Hearth Trouble in Hawthorne? We Meter It First

Pilot Out? Flame Sooty?

Leave your number and say what the gas unit is doing. We phone back with the service that fits and its price.

Parts MeteredCO ReadingPrice on paper first
Written Quote Before Work
Meter Readings on Gas Parts
Photos With Every Report
CO Reading on Gas Visits
Based in Hawthorne
Prices Listed Up Front
NFPA 211 Inspection Levels
Written Quote Before Work
Meter Readings on Gas Parts
Photos With Every Report
CO Reading on Gas Visits
Based in Hawthorne
Prices Listed Up Front
NFPA 211 Inspection Levels
Dooley Services, Hawthorne

Pilots, valves and glass up front. Brick and flue work when the vent needs it.

Each card names the parts involved and what the job covers, so the quote you get later reads the same way.

01

Chimney Sweep

Wood-burning flues brushed clear of soot and glaze, the smoke shelf scraped, and a note on anything the brushes uncovered.

Rotary rods run from the firebox to the cap
Smoke shelf and damper ledge scraped by hand
Glazed creosote flagged if brushing will not lift it
Drop cloths and a HEPA vacuum at the hearth
What the job covers
02

Chimney Inspection

A ranked look at crown, flue, damper and firebox, with gas connections and vent paths included whenever a gas appliance shares the chimney.

Level picked on the call, based on what changed
Crown, cap and flashing seen from the roof
Flue tile or metal liner checked for gaps
Gas vent connector and draft hood looked over
What the job covers
03

Chimney Repair

Cracked crowns, open mortar joints and broken flue tile repaired, scoped in writing first so you know which faults touch the gas appliance.

Each fault photographed and named in the scope
Crown cracks sealed or the crown poured new
Open joints ground out and repacked
Broken flue tile repaired or the flue relined
What the job covers
04

Fireplace Inspection

Room-side check of firebox, damper, hearth and surround, plus the gas valve, burner and glass when the fireplace runs on gas.

Firebox walls and floor checked for cracks
Damper worked open and shut, its seal judged
Hearth extension and mantel clearance measured
Gas valve and rating plate located
What the job covers
05

Fireplace Repair

Cracked panels, loose firebrick, worn doors and smoke spilling into the room, each traced to the faulty part before anything is ordered.

Rating plate read before ordering any part
Refractory panels and firebrick replaced
Glass doors rehung and their gaskets renewed
Smoke spill traced to draft, damper or opening size
What the job covers
06

Chimney Level 2 Inspection

Camera survey of the full flue for a sale, a new gas appliance or a quake, recorded and written up for whoever needs it.

Camera fed from the firebox or the roof
Liner joints, offsets and cracks recorded on video
Attic and roof sections checked where reachable
Gas appliance venting reviewed on the same visit
What the job covers
07

Chimney Cap Installation

Stainless caps with spark mesh, measured to the flue tile, fastened for Santa Ana gusts and matched to gas or wood exhaust.

Flue tile measured on the roof
Stainless top with spark mesh
Vent style matched to gas or wood use
Fastened to resist Santa Ana gusts
What the job covers
08

Chimney Flashing Repair

Leaks at the roofline traced and stopped with new step and counter pieces cut into the mortar, not smeared over with sealant.

Ceiling or attic stain matched to the roofline gap
Step pieces woven under each shingle course
Counter pieces set into a fresh mortar cut
Cricket added behind a wide chimney when needed
What the job covers
09

Chimney Masonry Repair

Sandy joints, flaking brick faces and white salt stains on the stack repaired with mortar and brick that match the old work.

Worn joints ground out and repacked
Mortar matched in color and strength
Spalled brick cut out and replaced
Salt streaks cleaned and the water path found
What the job covers
10

Chimney Rebuilds

A leaning, shifted or cracked stack taken down and laid back up, with steel or a framed top where the city calls for it.

Reasons a patch will not hold, written up first
Upper courses replaced above the roof
Full stacks laid up from the footing
Steel or a framed top to meet seismic rules
What the job covers
11

Fireplace Cleaning

Room-side cleanup of firebox, grate, glass doors and smoke-stained brick or tile, kept apart from the sweep that works inside the flue.

Ash shoveled out and the firebox vacuumed
Firebox walls scraped of loose soot
Smoke shadow scrubbed off brick or tile
Glass doors washed, seals looked over
What the job covers
12

Gas Fireplace Cleaning

Yearly gas hearth service: burner ports cleared, pilot and sensor cleaned, glass film lifted, logs reset and the vent checked for draft.

Glass removed and the white film lifted
Logs or glass media lifted and the tray vacuumed
Burner ports and pilot hood cleared of dust
Thermocouple or thermopile tip cleaned
What the job covers
13

Gas Fireplace Repair

Pilot outages, igniters that tick without lighting, weak flames and dead remotes, traced with a meter through the parts in firing order.

Symptom heard out before the panel comes off
Millivolt readings on thermocouple and thermopile
Igniter, spark gap and wiring tested
Valve and regulator checked for flow
What the job covers
14

Fireplace Remodel

New faces, mantels and gas conversions drawn up around the clearances your firebox and vent actually allow.

Firebox and flue checked before any design talk
Mantel height set to the clearance the unit needs
Stone, tile or plaster faces
Wood to gas conversions with a log set or insert
What the job covers
15

Fireplace Inserts

Sealed gas or wood boxes fitted into an existing opening, with a new liner to the top so the heat stays in the room.

Firebox measured before a unit is chosen
Gas, wood and electric options compared
Stainless liner run to the cap
Gas line run with a valve and leak tested
What the job covers
16

Pellet Stove Repair

Pellet stoves that stop feeding, fail to light or shut down on a fault code, repaired after a test of each motor and sensor.

Fault code read before parts are tested
Feed motor and auger tube cleared
Igniter element tested and replaced
Combustion and room fans serviced
What the job covers
17

Wood Stove Repair

Door ropes, baffles, firebrick and catalytic combustors on wood stoves replaced so the stove seals and burns at the rate it should.

Door rope and glass gasket replaced
Baffle boards and firebrick swapped when cracked
Catalytic combustor checked and renewed
Air control freed if it sticks
What the job covers
18

Gas Logs

Ceramic log sets over a gas burner, picked for your firebox and room, piped in and laid out so the flame burns clean.

Vented and vent-free sets compared for your room
Burner pan matched to the opening width and depth
Gas pipe run to the firebox with a valve key
Damper stop fitted on every vented set
What the job covers
19

Chimney Seismic Retrofit

Brick stacks braced, strapped or rebuilt lighter above the roof so a strong quake is less likely to drop bricks on the house.

Stack checked for loose courses and old cracks
Steel angle bracing fixed to the roof framing
Straps from the stack into the joists
Upper brick replaced with a lighter framed top
What the job covers
20

Chimney Crown Repair

Cracked or crumbling crowns sealed, patched or poured new with an overhang that throws rain away from the face of the stack.

Crown checked for cracks, gaps and lift at the tile
Fine cracks treated with a flexible crown sealer
Broken crowns chipped off and formed again
Overhang built in to throw rain off the brick
What the job covers
21

Dryer Vent Cleaning

Lint packed into the duct between dryer and outside hood cleared, so loads dry on one cycle and the duct stops running hot.

Transition hose pulled and inspected
Full duct run cleared to the outside hood
Crushed foil hose swapped for semi-rigid metal
Hood flap and screen cleared of lint
What the job covers
22

Chimney Liner Installation

Stainless liners for gas inserts, water heaters, furnaces and wood fireplaces, sized to the appliance and sealed at both ends.

Camera check of the old flue first
Diameter worked out from the appliance rating
Stainless liner fed down from the roof
Connection made at the insert, furnace or heater
What the job covers
23

Chimney Leak Repair

Water in the attic, a wet ceiling or a rusted damper traced to its entry point and stopped, priced once the source is known.

Stain inside matched to a spot on the roof
Hose test run on cap, crown and flashing in turn
Water inside gas vents and fireboxes traced
Fix aimed at the entry point, not the stain
What the job covers
24

Chimney Waterproofing

Breathable water repellent on brick and mortar that drinks rain, applied after cracks and joints are repaired, never over them.

Water absorbency tested with a spray first
Joints and crown repaired before any coating
Vapor-permeable repellent, never paint or film
Flood coat from the crown down to the roof
What the job covers
25

Chimney Damper Repair

Rusted, warped or seized dampers freed, rebuilt or swapped for a top-mounted unit, with a stop fitted when gas logs share the firebox.

Handle, pivot and plate checked through the swing
Rusted pins freed or the plate replaced
Top-mount damper with a cable to the firebox
Stop fitted where vented gas logs are used
What the job covers
26

Chimney Chase Cover

Rusted chase tops on factory-built fireplaces replaced in stainless, shaped to shed water and sealed where the vent pipe passes through.

Old top lifted and the framing checked for rot
Stainless top made to the chase size
Cross break so water runs off the edges
Drip hem bent along every side
What the job covers
Old cast-iron wood stove with a kettle on top

On a Gas Call

Panel off, meter on the pilot sensor, then valve, burner, glass and vent in turn.

Gas Hearths, Hawthorne

The reading picks the part, not a hunch.

Dooley Chimney Group follows NFPA 211 inspection levels in Hawthorne and writes each finding in plain words beside its price.

A gas fireplace fails in a set order: igniter, pilot, sensor, valve, burner. We test them in that order with a meter, so the part we replace is the one that actually failed. You hear which signs an owner can watch for, like a weak blue pilot or haze on the glass, and which jobs need a technician.

Above the unit sits the vent or the old brick flue it uses. We sweep, inspect, cap and reline those too, because a clean burner is no use under a blocked or cracked flue.

Thermocouple and thermopile output read in millivolts

Gas leak check before the panel goes back on

Carbon monoxide measured after every gas call

Each repair priced on paper before work

Owner or Technician?

We tell you which signs you can watch and which need us.

A weak pilot or cloudy glass can wait for the yearly service. Soot or a valve fault is a service call. A gas smell means leaving the house and phoning the gas company first.

Readings, Not Hunches

Thermocouples, valves and igniters get a meter on them before we name a part. You see the number and hear what it means.

Price Before Tools

Every repair goes on paper with its price before a tool comes out. Nothing gets added once we are on the roof.

Gas Checks on Every Call

Any visit that touches a gas appliance ends with a leak check and a carbon monoxide reading, whatever we came for.

South Bay Roofs

Our work centers on Hawthorne and the towns around it, where marine air rusts caps and chase tops faster than it does inland.

Out From Hawthorne

Where Dooley vans go each week

Hawthorne, Inglewood, Manhattan Beach and Lomita come first, then the rest of the county. 140 town pages list the hearths, vents and roofs we meet in each.

Local wear

Three South Bay conditions we plan for

A beach block in Manhattan Beach, a 1950s street in Hawthorne and a condo row in Inglewood each wear a hearth in a different way. The report says which one is at work on yours.

Postwar brick now venting gas

Many South Bay houses from the 1940s and 1950s still use their first brick flue, now carrying gas exhaust. A camera shows whether the tile cracked in the 1994 quake or is wearing from wet exhaust.

Shared flues and condo rules

Condo and townhouse rows often stack factory-built units under one roof. We note which parts belong to the unit and which to the HOA before quoting.

Salt air near the beach

Close to the water, galvanized chase tops, caps and screws rust quickly. Coastal jobs get stainless parts, and the report shows the rust that called for them.

Five Stages

What happens between your message and a clean flame

Gas faults get traced in the order a unit fires. Here is how the whole job runs, start to finish.

01

Tell Us What It Does

Use the form and say what the fireplace is doing: no pilot, a ticking igniter, soot on the logs, a smell. If you can read the brand on the rating plate, add it.

02

A Call Back With a Plan

We say which visit fits, what it costs from our price list, and what we need to reach: the valve, the roof or the attic.

03

Test Before Replace

On site we meter the gas parts in firing order and work the chimney from the cap down. No part is swapped on a hunch.

04

Findings on Paper

You get photos, the readings we took and a short list of what needs work, each item with its price written beside it.

05

Relight and Hand Back

After any repair we relight the unit with you, take a carbon monoxide reading and leave notes for the next service.

Request a Visit

Office hours run 7:00 AM to 7:00 PM, Monday through Sunday. Send the form any time.

Before the Cold Nights

Pilot dropping or logs going black in Hawthorne? Get it metered and priced

One visit traces the fault through igniter, pilot, sensor and valve, then gives you the reading and the repair price before any part goes in. Leave your number below.

Go to the contact page

Office hours 7:00 AM to 7:00 PM, weekends too

Send the symptom

Name, number and what the unit does. We phone back with the service that fits and its price.

By sending, you agree Dooley Chimney Group may contact you by call, automated text or email about your request. Consent isn't required to buy. Msg & data rates may apply; reply STOP to opt out. Privacy Policy

Hearth Questions

Pilots, logs, glass and the rules around them

Pilots, sensors, log sets, no-burn days and inspection levels, as owners around Hawthorne ask about them. Something else? Use the contact form.

Nine times out of ten the fault sits beside the pilot flame. A thermocouple, or a thermopile on units with a wall switch, heats in that flame and makes a tiny voltage that keeps the gas valve open. Dirty, worn or bent out of the flame, it stops making enough, and the valve shuts as soon as the knob is released. We clean it, read it with a meter and replace it if the number stays low.
Leave the house first, with everyone in it. Skip the light switches, do not light anything and do not hunt for the leak. Once you are outdoors, phone the utility, or 911 if the smell is strong. After the gas company has made the line safe, we can come out and repair the valve, the flex connector or the fitting that let it go.
Yes. Under California law the trigger is any one of three things: an appliance that burns fuel, a fireplace of any type, or a garage attached to the house. A gas hearth ticks the first two boxes on its own. Put an alarm in the room with the fireplace and one outside each sleeping area. An alarm tells you something already went wrong; the yearly service is what keeps it from going wrong.
You can. Hawthorne sits under the South Coast Air Quality Management District, which may declare a wood-burning ban on winter days when the air is poor. The ban covers wood in fireplaces and stoves; gas units are exempt. That exemption is one of the reasons so many South Bay owners switch an old wood opening over to a log set or an insert.
Use a Level 1, $53, for a chimney that is used the way it always has been. Pick a Level 2, $380, after a change: a sale, a new insert or log set, a relined flue, a quake or a flue fire. It brings video of the flue. You will seldom need a Level 3. We raise it only when a Level 2 has turned up a reason, because it involves opening up a section of wall or masonry to reach what the camera could not show.
Rarely, and never as the first visit. It follows a Level 2 that showed damage the camera could not fully see, such as a broken flue section hidden in a wall or rot around a chase. Because the hidden area has to be opened, you get the scope and the price on paper first and decide from there.
It is two flues, even inside one brick stack, and each one gets its own check. The fireplace side and the water heater or furnace side wear differently: a cracked tile on one, a rusted connector on the other. When you book, tell us every fireplace and every gas appliance that vents up the chimney, and the quote will list each one.
Brick jobs swing on things we cannot know from a phone call: how many courses are damaged, how the roof can be reached and whether the flue needs work too. We look, photograph and write a scope with a price on each line. Fixed prices on this site cover sweeps, inspections, caps, crickets, leak repair and gas inserts.
Mineral residue from burning gas. It bakes harder every season, and ordinary glass cleaner only smears it around. Our yearly service lifts it with a ceramic glass polish while the panel is out, and a new gasket goes on if the old one has flattened.
Your call. A standing pilot burns a little gas all year and warms the room a touch. Shutting it off saves that gas, but spiders and dust settle in the pilot tube over the warm months, a common reason a pilot refuses to light in October. If you turn it off, book the cleaning before the first cold night rather than after.
Soot means the gas is not burning all the way. Logs out of their spots, a blocked burner port, a damper that is only half open or a badly set air shutter can each cause it. Stop using the fireplace and book a service, because incomplete burning also makes carbon monoxide.
In most homes. A log set is the simplest change and keeps the look of an open fire. An insert closes the opening and gives far more heat, at $2,700 to $5,450 installed. A house with no fireplace at all can have a direct-vent unit put on an outside wall for $4,350 to $8,700. Either way we check the firebox, the flue and the gas supply first.
Call (323) 524-5172